Bass Instruments, EMDE.PF Partially full pipe electromagnetic flowmeter is a kind of measuring instrument that uses the velocity field method to continuously measure the liquid flow in pipelines. It can measure and display data such as instantaneous flow, flow rate and cumulative flow.
Typical response time: 24 Hours
| PROPERTY | DETAILS |
|---|---|
| Output | Pulse |
| Accuracy | <±0,5% O.D. Ops.<±0,2% |
| Temperature | -20...120°C, Ops.180°C |
| Protection | IP67, IP68 |
| Wet Parts | PTFE, PP, Hard Rubber, PFA |
| Pressure | 16 Bar max. Ops.100 Bar |
| Supply | 24V DC, 230VAC or Battery |
| Connection Size | DN10...DN3000 |
| Display | Instantaneous and Total, On-Unit or Wall-Mounted Type |
| Measuring Range-Liquid | 0,1-10 m/s |
| Electrodes | AISI316L, Ti, Hastelloy-C, vb. |
| Applied Pipe Diameters | DN15...DN1200 |
| Communications | RS485-MODBUS, M-BUS, HART |
| Application | Conductive Liquids |
Standard safety certified
International standard
High-risk certified